Difference between revisions of "HMC Operations"
From MidrangeWiki
MrDolomite (talk | contribs) m (→Is there a redbook on V7 of HMC code?: use Template:Redpiece) |
Starbuck5250 (talk | contribs) m (→What versions of firmware are required for the various levels of IBM i?: formatting) |
||
(31 intermediate revisions by 8 users not shown) | |||
Line 1: | Line 1: | ||
− | |||
== Operations == | == Operations == | ||
=== How to view Firmware Levels === | === How to view Firmware Levels === | ||
Line 5: | Line 4: | ||
# In V5R4'''M5''' and above IBM added the command DSPFMWSTS. I still prefer using the HMC because the help on that at least explains what they mean. | # In V5R4'''M5''' and above IBM added the command DSPFMWSTS. I still prefer using the HMC because the help on that at least explains what they mean. | ||
=== What versions of HMC support which versions of firmware? === | === What versions of HMC support which versions of firmware? === | ||
− | # https://www14.software.ibm.com/webapp/set2/sas/f/power5cm/supportedcode.html | + | # Determining if your server firmware level and HMC machine code level are compatible [https://www14.software.ibm.com/webapp/set2/sas/f/power5cm/supportedcode.html] |
− | # | + | |
− | + | === What versions of firmware are required for the various levels of IBM i? === | |
− | + | # 7.2 requires a minimum firmware level of EM320_040 / EL320_040 / EA320_040 / EH330_034 for POWER6 systems; AL710_043 / AM710_065 / AA710_083 / AH720_064 for POWER7 systems; SV810_054 for POWER8 systems. [http://www-912.ibm.com/s_dir/slkbase.NSF/DocNumber/408316083] | |
− | # | + | # V7R1 requires a minimum firmware level of SF240_332 for POWER5™ based systems; EA320_040, EL320_040, EM320_040, EH330_034 depending on the model for POWER6™ based systems; and AL710_043, AM710_065, AA710_083, AH720_064 depending on the model for POWER7™ based systems. SV810_054 for POWER8 systems. [http://www-912.ibm.com/s_dir/SLKBase.nsf/DocNumber/408316083] |
+ | # V6R1 requires a minimum firmware level of SF240_332 for POWER5™ based systems and EA320_040, EL320_040, EM320_040 depending on the model for POWER6™ based systems. [http://www-912.ibm.com/s_dir/slkbase.NSF/c32447c09fb9a1f186256a6c00504227/23c4789ba6f5321886256fd300586b7f?OpenDocument] | ||
+ | # V5R4 requires a minimum firmware level of SF235_160. [http://www-912.ibm.com/s_dir/slkbase.NSF/c32447c09fb9a1f186256a6c00504227/23c4789ba6f5321886256fd300586b7f?OpenDocument] | ||
+ | * [http://www-912.ibm.com/s_dir/slkbase.NSF/DocNumber/408316083 IBM Software Technical Document number 408316083 "Master Document for Server Firmware and HMC Code Wizard"] | ||
+ | |||
=== How do I obtain new levels of HMC code? === | === How do I obtain new levels of HMC code? === | ||
# Through Fix Central at<br>http://www-912.ibm.com/eserver/support/fixes/fixcentral<br>selecting System i family and Hardware Management Console | # Through Fix Central at<br>http://www-912.ibm.com/eserver/support/fixes/fixcentral<br>selecting System i family and Hardware Management Console | ||
+ | # Or download it at Support and Downloads [https://www14.software.ibm.com/webapp/set2/sas/f/hmc/home.html] by selecting platform, Version, Release | ||
=== How do I obtain new levels of firmware? === | === How do I obtain new levels of firmware? === | ||
# First, IMNSHO, you should have your system configured so that your firmware is HMC managed and not updated by upgrades to the OS of a particular lpar. This will help prevent you from getting a firmware upgrade so advanced that your HMC will no longer support it. | # First, IMNSHO, you should have your system configured so that your firmware is HMC managed and not updated by upgrades to the OS of a particular lpar. This will help prevent you from getting a firmware upgrade so advanced that your HMC will no longer support it. | ||
Line 19: | Line 23: | ||
# http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/topic/iphbk/iphblservicepartition.htm | # http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/topic/iphbk/iphblservicepartition.htm | ||
=== How do I access the ASMI? === | === How do I access the ASMI? === | ||
− | # http://publib.boulder.ibm.com/infocenter/ | + | ==== For Power 8 ==== |
+ | # http://www-01.ibm.com/support/knowledgecenter/8286-41A/p8hby/asmihmc.htm | ||
+ | ==== For Power 7 ==== | ||
+ | # http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/p7hby/asmihmc.htm | ||
+ | ==== For Power 6 ==== | ||
+ | # http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/iphby/asmihmc.htm | ||
+ | ==== For Power 5 ==== | ||
+ | # http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/iphby_p5/asmihmc.htm | ||
+ | |||
=== If I upgrade to V7 of HMC code what will the interface look like? === | === If I upgrade to V7 of HMC code what will the interface look like? === | ||
# https://www-01.ibm.com/servers/resourcelink/lib03030.nsf/pagesByDocid/6DC24478DD66D14C852572E3005A70B3?OpenDocument | # https://www-01.ibm.com/servers/resourcelink/lib03030.nsf/pagesByDocid/6DC24478DD66D14C852572E3005A70B3?OpenDocument | ||
Line 30: | Line 42: | ||
=== If I knew how to do something in V6 (or earlier) how do I do it in V7? === | === If I knew how to do something in V6 (or earlier) how do I do it in V7? === | ||
# http://www-1.ibm.com/support/docview.wss?uid=nas1910ab0261c310f74862572e40072c940 | # http://www-1.ibm.com/support/docview.wss?uid=nas1910ab0261c310f74862572e40072c940 | ||
+ | |||
+ | [[#top]] | ||
+ | |||
+ | === HMC questions - installing WebSM (not needed for V7 and above) === | ||
+ | |||
+ | original post [http://archive.midrange.com/midrange-l/200512/msg01292.html] | ||
+ | |||
+ | Instructions are here: | ||
+ | |||
+ | http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp?topic=/iphai/remotehmc.htm | ||
+ | |||
+ | |||
+ | [[#top]] | ||
== Configuration == | == Configuration == | ||
+ | === How do I configure a session on my PC to act as the 5250 console session for a particular lpar controlled by the HMC? === | ||
+ | http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/topic/iphb8/remote5250.htm | ||
+ | |||
+ | [[#top]] | ||
+ | |||
=== How to print a rack config from an [[HMC]] managed system === | === How to print a rack config from an [[HMC]] managed system === | ||
# Printing Rack config information (see also "Printing I/O information") | # Printing Rack config information (see also "Printing I/O information") | ||
Line 40: | Line 70: | ||
## F6 to Print Configuration | ## F6 to Print Configuration | ||
## Take the defaults on Print Format Options (use 132 columns). | ## Take the defaults on Print Format Options (use 132 columns). | ||
+ | # Printing information from a vios partition | ||
+ | ## Download a putty client <br>(Sample - http://www.chiark.greenend.org.uk/~sgtatham/putty/) | ||
+ | ##* Now in putty, verify you used the ssh protocol. Say yes when it gives you a security warning. | ||
+ | ##* If you still have problems verify that you can ping your vios lpar. Verify that any firewall between you and the vios lpar allows port 22.<br> | ||
+ | ## Start your putty client to your vios lpar. Use the same userid's and password you normally use to log on to your vios lpar. | ||
+ | ## In your putty client click on the top left icon and pick 'Change settings'. Expand Session, select Logging. Change to Printable output. Pick a log file name you like. | ||
+ | ## Enter in the command oem_setup_env. This enters an AIX like shell. You will change from a $ prompt to a # prompt. | ||
+ | ## Enter in the command lscfg -pv. This will display the desired information. | ||
+ | ## Use e to exit iprconfig. | ||
+ | ## Type in exit (in lower case) to exit your linux terminal. | ||
+ | ## Open the log file you specified earlier. Trim any stuff off you don't want. | ||
+ | # Printing dedicated, non guested, Linux lpar information | ||
+ | ## Download a putty client <br>(Sample - http://www.chiark.greenend.org.uk/~sgtatham/putty/) | ||
+ | ##* Now in putty, verify you used the ssh protocol. Say yes when it gives you a security warning. | ||
+ | ##* If you still have problems verify that you can ping your Linux lpar. Verify that any firewall between you and the Linux lpar allows port 22.<br> | ||
+ | ## Start your putty client to your Linux lpar. Use the same userid's and password you normally use to log on to your linux lpar. (hint: A default user id is root.) | ||
+ | ## Enter in the command iprconfig. | ||
+ | ## 1. Display hardware status. Highlight desired text. Use Ctrl-C, it will break you out of iprconfig but then you can use Ctrl-V to paste the contents into notepad or some such thing. | ||
+ | ## Use e to exit iprconfig. | ||
+ | ## Type in exit (in lower case) to exit your linux terminal. | ||
# Printing I/O information | # Printing I/O information | ||
## Download a putty client <br>(Sample - http://www.chiark.greenend.org.uk/~sgtatham/putty/) | ## Download a putty client <br>(Sample - http://www.chiark.greenend.org.uk/~sgtatham/putty/) | ||
Line 46: | Line 96: | ||
##* Using the HMC system manager GUI, select HMC Management, then HMC Configuration. In the right-hand panel click on "enable or disable remote command execution". Verify the box is checked. Click ok. | ##* Using the HMC system manager GUI, select HMC Management, then HMC Configuration. In the right-hand panel click on "enable or disable remote command execution". Verify the box is checked. Click ok. | ||
##* Enable ssh in the firewall: | ##* Enable ssh in the firewall: | ||
− | ##**Using the HMC system manager GUI, select HMC Management, then HMC Configuration. In the right-hand panel click on "Customize Network Settings". In the "Customize Network Settings" dialog click the "Lan Adapter" tab, select the lan adapter connected to your network (usually eth1), click the "Details" button. On the Details panel, click the Firewall tab. In the top list box click "Secure Shell 22:tcp". Click the "Allow Incoming" button. CLick ok on each panel to exit. It will tell you that you must reboot but this is not necessary. Firewall settings go into affect immediately. | + | ##**Using the HMC system manager GUI, select HMC Management, then HMC Configuration. |
+ | ##***In the right-hand panel click on "Customize Network Settings". | ||
+ | ##***In the "Customize Network Settings" dialog click the "Lan Adapter" tab, | ||
+ | ##***select the lan adapter connected to your network (usually eth1), click the "Details" button. | ||
+ | ##***On the Details panel, click the Firewall tab. | ||
+ | ##***In the top list box click "Secure Shell 22:tcp". | ||
+ | ##***Click the "Allow Incoming" button. | ||
+ | ##***CLick ok on each panel to exit. | ||
+ | ##***It will tell you that you must reboot but this is not necessary. Firewall settings go into affect immediately. | ||
##* Now in putty, verify you used the ssh protocol. Say yes when it gives you a security warning. | ##* Now in putty, verify you used the ssh protocol. Say yes when it gives you a security warning. | ||
##* If you still have problems verify that you can ping your HMC. Verify that any firewall between you and the HMC allows port 22.<br> | ##* If you still have problems verify that you can ping your HMC. Verify that any firewall between you and the HMC allows port 22.<br> | ||
Line 53: | Line 111: | ||
##* lssyscfg -r sys -F name | ##* lssyscfg -r sys -F name | ||
##* Take a name from that list and put it in the double quotes instead of sysname: | ##* Take a name from that list and put it in the double quotes instead of sysname: | ||
− | ##* lshwres -r io --rsubtype slot -m "sysname" -F bus_id,phys_loc,vpd_type,description,lpar_name | + | ##* lshwres -r io --rsubtype slot -m "sysname" -F unit_phys_loc,bus_id,phys_loc,vpd_type,description,lpar_name |
## From your putty client, Copy all to Clipboard. Paste that into your favorite tool like Word, Excel, etc. | ## From your putty client, Copy all to Clipboard. Paste that into your favorite tool like Word, Excel, etc. | ||
+ | |||
+ | # An alternative would be to use the System Plan functionality supplied with the HMC v7 | ||
+ | |||
+ | [[#top]] | ||
=== How to print a rack config from a non [[LPAR]] system === | === How to print a rack config from a non [[LPAR]] system === | ||
Line 63: | Line 125: | ||
# F6 to Print Configuration | # F6 to Print Configuration | ||
# Take the defaults on Print Format Options (use 132 columns). | # Take the defaults on Print Format Options (use 132 columns). | ||
+ | |||
+ | [[#top]] | ||
+ | |||
=== How to print a rack config from a non-i5 [[LPAR]] system === | === How to print a rack config from a non-i5 [[LPAR]] system === | ||
# In the primary partition signon to the iSeries with an appropriate userid | # In the primary partition signon to the iSeries with an appropriate userid | ||
Line 71: | Line 136: | ||
# At the Level of detail to display field, type *ALL to set the level of detail to ALL. | # At the Level of detail to display field, type *ALL to set the level of detail to ALL. | ||
# F6 to print the system resources (use 132 columns). | # F6 to print the system resources (use 132 columns). | ||
+ | |||
+ | [[#top]] | ||
+ | |||
+ | === How to export a system plan for use by System Planner or your BP === | ||
+ | * Use a putty client to connect to your HMC | ||
+ | * List existing system plans on your HMC | ||
+ | lssysplan | ||
+ | name=MAILTWO.sysplan,description=System plan created from Server-9408-M25-SN102EF8C,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Aug 25, 2008 3:10:58 PM" | ||
+ | name=Server-9408-M25-SN102EF8C.sysplan,description=System plan created from Server-9408-M25-SN102EF8C,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Sep 22, 2008 11:42:56 AM" | ||
+ | name=Server-9406-MMA-SN103BDDD.sysplan,description=System plan created from Server-9406-MMA-SN103BDDD,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Sep 29, 2008 11:54:30 AM" | ||
+ | |||
+ | * Remove existing system plans on your HMC | ||
+ | rmsysplan -f MAILTWO.sysplan | ||
+ | rmsysplan -f Server-9408-M25-SN102EF8C.sysplan | ||
+ | rmsysplan -f Server-9406-MMA-SN103BDDD.sysplan | ||
+ | lssysplan | ||
+ | No results were found. | ||
+ | * List servers supported by this HMC. | ||
+ | lssyscfg -r sys -F name | ||
+ | Server-9408-M25-SN102EF8C | ||
+ | Server-9406-MMA-SN103BDDD | ||
+ | Server-9408-M25-SN10C2091 | ||
+ | * Make a system plan for each server supported by this HMC | ||
+ | mksysplan -f Server-9408-M25-SN102EF8C.sysplan -m Server-9408-M25-SN102EF8C | ||
+ | mksysplan -f Server-9408-M25-SN10C2091.sysplan -m Server-9408-M25-SN10C2091 | ||
+ | mksysplan -f Server-9406-MMA-SN103BDDD.sysplan -m Server-9406-MMA-SN103BDDD | ||
+ | |||
+ | * List the system plans you just created. | ||
+ | lssysplan | ||
+ | name=Server-9408-M25-SN102EF8C.sysplan,description=,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Sep 30, 2008 11:40:37 AM" | ||
+ | name=Server-9408-M25-SN10C2091.sysplan,description=,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Sep 30, 2008 11:45:32 AM" | ||
+ | name=Server-9406-MMA-SN103BDDD.sysplan,description=,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Sep 30, 2008 11:55:45 AM" | ||
+ | |||
+ | * Export your system plans via ftp to some server. | ||
+ | cpsysplan -r ftp -f Server-9408-M25-SN102EF8C.sysplan -o export -h 10.10.1.211 -u ROB --passwd MCCAIN08 -d /rob | ||
+ | cpsysplan -r ftp -f Server-9408-M25-SN10C2091.sysplan -o export -h 10.10.1.211 -u ROB --passwd MCCAIN08 -d /rob | ||
+ | cpsysplan -r ftp -f Server-9406-MMA-SN103BDDD.sysplan -o export -h 10.10.1.211 -u ROB --passwd MCCAIN08 -d /rob | ||
+ | |||
+ | [[#top]] | ||
+ | |||
+ | == Misc == | ||
+ | === How do I do a screen print of a HMC screen === | ||
+ | Document Number: 358236751 | ||
+ | |||
+ | Document Title: | ||
+ | [http://www-01.ibm.com/support/docview.wss?uid=nas8N1015824] | ||
+ | Capturing Screen Shots from the HMC | ||
+ | |||
+ | *Imagemagick (Open Source) as recommended in the Document is useful to view the files. | ||
+ | *I found HMCWIN in a one line window, and Sendfile to send to the IFS simplest to use, but I think a PuTTY client may be easiest. | ||
+ | [[User:FKOL|FKOL]] 00:50, 23 April 2008 (CDT) | ||
+ | |||
+ | [[#top]] | ||
+ | |||
+ | ==Categories== | ||
+ | [[Category:Operations]] | ||
+ | [[Category:HMC]] |
Latest revision as of 16:08, 15 January 2016
Contents
- 1 Operations
- 1.1 How to view Firmware Levels
- 1.2 What versions of HMC support which versions of firmware?
- 1.3 What versions of firmware are required for the various levels of IBM i?
- 1.4 How do I obtain new levels of HMC code?
- 1.5 How do I obtain new levels of firmware?
- 1.6 How do I configure an i5/OS lpar to be my service partition and apply firmware upgrades?
- 1.7 How do I access the ASMI?
- 1.8 If I upgrade to V7 of HMC code what will the interface look like?
- 1.9 Is there a redbook on V7 of HMC code?
- 1.10 If I knew how to do something in V6 (or earlier) how do I do it in V7?
- 1.11 HMC questions - installing WebSM (not needed for V7 and above)
- 2 Configuration
- 2.1 How do I configure a session on my PC to act as the 5250 console session for a particular lpar controlled by the HMC?
- 2.2 How to print a rack config from an HMC managed system
- 2.3 How to print a rack config from a non LPAR system
- 2.4 How to print a rack config from a non-i5 LPAR system
- 2.5 How to export a system plan for use by System Planner or your BP
- 3 Misc
- 4 Categories
Operations
How to view Firmware Levels
- http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/topic/ipha5/viewexistlevel.htm
- In V5R4M5 and above IBM added the command DSPFMWSTS. I still prefer using the HMC because the help on that at least explains what they mean.
What versions of HMC support which versions of firmware?
- Determining if your server firmware level and HMC machine code level are compatible [1]
What versions of firmware are required for the various levels of IBM i?
- 7.2 requires a minimum firmware level of EM320_040 / EL320_040 / EA320_040 / EH330_034 for POWER6 systems; AL710_043 / AM710_065 / AA710_083 / AH720_064 for POWER7 systems; SV810_054 for POWER8 systems. [2]
- V7R1 requires a minimum firmware level of SF240_332 for POWER5™ based systems; EA320_040, EL320_040, EM320_040, EH330_034 depending on the model for POWER6™ based systems; and AL710_043, AM710_065, AA710_083, AH720_064 depending on the model for POWER7™ based systems. SV810_054 for POWER8 systems. [3]
- V6R1 requires a minimum firmware level of SF240_332 for POWER5™ based systems and EA320_040, EL320_040, EM320_040 depending on the model for POWER6™ based systems. [4]
- V5R4 requires a minimum firmware level of SF235_160. [5]
How do I obtain new levels of HMC code?
- Through Fix Central at
http://www-912.ibm.com/eserver/support/fixes/fixcentral
selecting System i family and Hardware Management Console - Or download it at Support and Downloads [6] by selecting platform, Version, Release
How do I obtain new levels of firmware?
- First, IMNSHO, you should have your system configured so that your firmware is HMC managed and not updated by upgrades to the OS of a particular lpar. This will help prevent you from getting a firmware upgrade so advanced that your HMC will no longer support it.
- Through Fix Central at
http://www-912.ibm.com/eserver/support/fixes/fixcentral
selecting System i family and Server Firmware and Update policy set to HMC.
How do I configure an i5/OS lpar to be my service partition and apply firmware upgrades?
- First, IMNSHO, you should have your system configured so that your firmware is HMC managed and not updated by upgrades to the OS of a particular lpar. This will help prevent you from getting a firmware upgrade so advanced that your HMC will no longer support it. Therefore I do not recommend configuring an i5/os lpar to be your service partition.
- http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/topic/iphbk/iphblservicepartition.htm
How do I access the ASMI?
For Power 8
For Power 7
For Power 6
For Power 5
If I upgrade to V7 of HMC code what will the interface look like?
Is there a redbook on V7 of HMC code?
If I knew how to do something in V6 (or earlier) how do I do it in V7?
HMC questions - installing WebSM (not needed for V7 and above)
original post [7]
Instructions are here:
http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp?topic=/iphai/remotehmc.htm
Configuration
How do I configure a session on my PC to act as the 5250 console session for a particular lpar controlled by the HMC?
http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/topic/iphb8/remote5250.htm
How to print a rack config from an HMC managed system
- Printing Rack config information (see also "Printing I/O information")
- Printing information from a vios partition
- Download a putty client
(Sample - http://www.chiark.greenend.org.uk/~sgtatham/putty/)- Now in putty, verify you used the ssh protocol. Say yes when it gives you a security warning.
- If you still have problems verify that you can ping your vios lpar. Verify that any firewall between you and the vios lpar allows port 22.
- Start your putty client to your vios lpar. Use the same userid's and password you normally use to log on to your vios lpar.
- In your putty client click on the top left icon and pick 'Change settings'. Expand Session, select Logging. Change to Printable output. Pick a log file name you like.
- Enter in the command oem_setup_env. This enters an AIX like shell. You will change from a $ prompt to a # prompt.
- Enter in the command lscfg -pv. This will display the desired information.
- Use e to exit iprconfig.
- Type in exit (in lower case) to exit your linux terminal.
- Open the log file you specified earlier. Trim any stuff off you don't want.
- Download a putty client
- Printing dedicated, non guested, Linux lpar information
- Download a putty client
(Sample - http://www.chiark.greenend.org.uk/~sgtatham/putty/)- Now in putty, verify you used the ssh protocol. Say yes when it gives you a security warning.
- If you still have problems verify that you can ping your Linux lpar. Verify that any firewall between you and the Linux lpar allows port 22.
- Start your putty client to your Linux lpar. Use the same userid's and password you normally use to log on to your linux lpar. (hint: A default user id is root.)
- Enter in the command iprconfig.
- 1. Display hardware status. Highlight desired text. Use Ctrl-C, it will break you out of iprconfig but then you can use Ctrl-V to paste the contents into notepad or some such thing.
- Use e to exit iprconfig.
- Type in exit (in lower case) to exit your linux terminal.
- Download a putty client
- Printing I/O information
- Download a putty client
(Sample - http://www.chiark.greenend.org.uk/~sgtatham/putty/) - Set up the HMC for this.
To enable SSH on the HMC you must do the following:- Start the ssh daemon:
- Using the HMC system manager GUI, select HMC Management, then HMC Configuration. In the right-hand panel click on "enable or disable remote command execution". Verify the box is checked. Click ok.
- Enable ssh in the firewall:
- Using the HMC system manager GUI, select HMC Management, then HMC Configuration.
- In the right-hand panel click on "Customize Network Settings".
- In the "Customize Network Settings" dialog click the "Lan Adapter" tab,
- select the lan adapter connected to your network (usually eth1), click the "Details" button.
- On the Details panel, click the Firewall tab.
- In the top list box click "Secure Shell 22:tcp".
- Click the "Allow Incoming" button.
- CLick ok on each panel to exit.
- It will tell you that you must reboot but this is not necessary. Firewall settings go into affect immediately.
- Using the HMC system manager GUI, select HMC Management, then HMC Configuration.
- Now in putty, verify you used the ssh protocol. Say yes when it gives you a security warning.
- If you still have problems verify that you can ping your HMC. Verify that any firewall between you and the HMC allows port 22.
- Start your putty client to your HMC. Use the same userid's and password you normally use to log on to your HMC. (hint: A default user id is hscroot. A default password may be abc123)
- Enter the first command to get a list of systems managed by this HMC:
- lssyscfg -r sys -F name
- Take a name from that list and put it in the double quotes instead of sysname:
- lshwres -r io --rsubtype slot -m "sysname" -F unit_phys_loc,bus_id,phys_loc,vpd_type,description,lpar_name
- From your putty client, Copy all to Clipboard. Paste that into your favorite tool like Word, Excel, etc.
- Download a putty client
- An alternative would be to use the System Plan functionality supplied with the HMC v7
How to print a rack config from a non LPAR system
- Signon to the iSeries with an appropriate userid
- On a command line perform command STRSST
- Select option 1 Start a service tool
- Select option 7 Hardware service manager
- F6 to Print Configuration
- Take the defaults on Print Format Options (use 132 columns).
How to print a rack config from a non-i5 LPAR system
- In the primary partition signon to the iSeries with an appropriate userid
- On a command line perform command STRSST
- Select option 5 Work with partitions
- Select option 1 Display partition information
- Select option 5 Display system I/O resources
- At the Level of detail to display field, type *ALL to set the level of detail to ALL.
- F6 to print the system resources (use 132 columns).
How to export a system plan for use by System Planner or your BP
- Use a putty client to connect to your HMC
- List existing system plans on your HMC
lssysplan name=MAILTWO.sysplan,description=System plan created from Server-9408-M25-SN102EF8C,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Aug 25, 2008 3:10:58 PM" name=Server-9408-M25-SN102EF8C.sysplan,description=System plan created from Server-9408-M25-SN102EF8C,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Sep 22, 2008 11:42:56 AM" name=Server-9406-MMA-SN103BDDD.sysplan,description=System plan created from Server-9406-MMA-SN103BDDD,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Sep 29, 2008 11:54:30 AM"
- Remove existing system plans on your HMC
rmsysplan -f MAILTWO.sysplan rmsysplan -f Server-9408-M25-SN102EF8C.sysplan rmsysplan -f Server-9406-MMA-SN103BDDD.sysplan lssysplan No results were found.
- List servers supported by this HMC.
lssyscfg -r sys -F name
Server-9408-M25-SN102EF8C Server-9406-MMA-SN103BDDD Server-9408-M25-SN10C2091
- Make a system plan for each server supported by this HMC
mksysplan -f Server-9408-M25-SN102EF8C.sysplan -m Server-9408-M25-SN102EF8C mksysplan -f Server-9408-M25-SN10C2091.sysplan -m Server-9408-M25-SN10C2091 mksysplan -f Server-9406-MMA-SN103BDDD.sysplan -m Server-9406-MMA-SN103BDDD
- List the system plans you just created.
lssysplan name=Server-9408-M25-SN102EF8C.sysplan,description=,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Sep 30, 2008 11:40:37 AM" name=Server-9408-M25-SN10C2091.sysplan,description=,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Sep 30, 2008 11:45:32 AM" name=Server-9406-MMA-SN103BDDD.sysplan,description=,source=HMC V7R3.3.0.1,version=HMC 1.4,"date=Sep 30, 2008 11:55:45 AM"
- Export your system plans via ftp to some server.
cpsysplan -r ftp -f Server-9408-M25-SN102EF8C.sysplan -o export -h 10.10.1.211 -u ROB --passwd MCCAIN08 -d /rob cpsysplan -r ftp -f Server-9408-M25-SN10C2091.sysplan -o export -h 10.10.1.211 -u ROB --passwd MCCAIN08 -d /rob cpsysplan -r ftp -f Server-9406-MMA-SN103BDDD.sysplan -o export -h 10.10.1.211 -u ROB --passwd MCCAIN08 -d /rob
Misc
How do I do a screen print of a HMC screen
Document Number: 358236751
Document Title: [8] Capturing Screen Shots from the HMC
- Imagemagick (Open Source) as recommended in the Document is useful to view the files.
- I found HMCWIN in a one line window, and Sendfile to send to the IFS simplest to use, but I think a PuTTY client may be easiest.
FKOL 00:50, 23 April 2008 (CDT)